Fehlerklärung in unter 2 Millisekunden bei 10.000A-Vollkurzschlüssen
Analoge Hardware-Schwellenwert-Komparatoren lösen pyrotechnische Trennelemente aus, bevor mechanische Schützkontakte verdampfen können, um Extremenergiepfade sicher zu isolieren.
Rogowski Coil dv/dt Detection
Using integrated Rogowski current sensors to detect current rise rates exceeding 100 A/microsecond, triggering the pyrofuse in hardware without waiting for MCU software loops.
- Sub-2 millisecond physical busbar severance under 10 kA fault currents.
- Hardware-direct trigger bypassing MCU software execution overhead.
- AEC-Q100 and ISO 26262 ASIL D qualified pyrotechnic squib drivers.
- Complete galvanic arc extinction via ceramic quenching chambers.